首页> 外文期刊>Propellants, Explosives, Pyrotechnics >Detection of military explosives by atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction
【24h】

Detection of military explosives by atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction

机译:大气压化学电离质谱联用逆流法检测军用炸药

获取原文
获取原文并翻译 | 示例
           

摘要

To detect vapors from explosives, we have developed a new detection system based on a novel ion source for atmospheric pressure chemical ionization (APCI). The direction of the sample gas flow introduced into the ion source. We call this technique "counter-flow introduction" (CFI). The CFI ion source has high ionization efficiency for nitro-compounds and is installed in an ion-trap mass spectrometer. Our tests on various military explosives show that this system is suitable for practical on-line explosive detection; namely major explosives can be detected within a few seconds without any pretreatment of the sample gases.
机译:为了检测爆炸物中的蒸气,我们开发了一种基于新型离子源的新型检测系统,用于大气压化学电离(APCI)。引入离子源的样品气流的方向。我们称这种技术为“逆流引入”(CFI)。 CFI离子源对硝基化合物具有高电离效率,并安装在离子阱质谱仪中。我们对各种军用炸药的测试表明,该系统适用于实际的在线炸药检测。也就是说,无需对样品气体进行任何预处理,即可在几秒钟内检测出主要爆炸物。