To study the tribological performance of metal-on-metal hip joint resurfacings, the wear performance of three pairs of Co-Cr-Mo alloy samples (pins and plates) were tested in a multidirectional pin-on-plate wear machine. An 'as-cast', a single-heat-treated, and a double-heat-treated set of specimens were tested to 3×10{sup}6 cycles. The two heat treatments resulted in partial and full solution of the carbides into the matrix. An increasing trend in wear rate was found from 'as-cast' to the double-heat-treated specimens. The as-cast specimens showed the lowest wear rate (1.69×10{sup}(-6)mm{sup}3/Nm), the reduced carbide samples had the next lowest wear rate (2.1×10{sup}(-6)mm{sup}3/Nm), while the specimens without carbides wore the most (2.41×10{sup}(-6)mm3/Nm).
机译:为了研究金属对金属髋关节表面的摩擦学性能,在多向销对板磨损机中测试了三对Co-Cr-Mo合金样品(销和板)的磨损性能。测试了“铸态”,单热处理和双热处理的一组样品,进行了3​​×10 6个循环。两次热处理导致碳化物部分和全部溶解到基体中。从“铸态”到双热处理试样,发现磨损率呈上升趋势。铸态试样的磨损率最低(1.69×10 {sup}(-6)mm {sup} 3 / Nm),还原碳化物样品的磨损率次之(2.1×10 {sup}(-6) )mm {sup} 3 / Nm),而不含碳化物的试样磨损最大(2.41×10 {sup}(-6)mm3 / Nm)。