An indwelling ruminal pH system has been used for the continuous recording of ruminal pH to evaluate subacute ruminal acidosis (SARA) in dairy cows. However this system does not allow the field application. The objective of this study was to develop a new radio transmission pH measurement system, and to assess its performance and usefulness in a continuous evaluation of ruminal pH for use on commercial dairy farms. The radio transmission pH measurement system consists of a wireless pH sensor, a data measurement receiver, a relay unit, and a personal computer installed special software. The pH sensor is housed in a bullet shaped bolus, which also encloses a pH amplifier circuit, a central processing unit (CPU) circuit, a radio frequency (RF) circuit, and a battery. The mean variations of the measurements by the glass pH electrode were +0.20 (n=10) after 2 months of continuous recording, compared to the values confirmed by standard pH solutions for pH 4 and pH 7 at the start of the recording. The mean lifetime of the internal battery was 2.5 months (n=10) when measurements were continuously transmitted every 10 min. Ruminal pH recorded by our new system was compared to that of the spot sampling of ruminal fluid. The mean pH for spot sampling was 6.36+or-0.55 (n=96), and the mean pH of continuous recording was 6.22+or-0.54 (n=96). There was a good correlation between continuous recording and spot sampling (r=0.986, P<0.01). We also examined whether our new pH system was able to detect experimentally induced ruminal acidosis in cows and to record long-term changes in ruminal pH. In the cows fed acidosis-inducing diets, the ruminal pH dropped markedly during the first 2 h following the morning feeding, and decreased moreover following the evening feeding, with many pulse-like pH changes. The pH of the cows showed the lowest values of 5.3-5.2 in the midnight time period and it recovered to the normal value by the next morning feeding. In one healthy periparturient cow, the circadian changes in ruminal pH were observed as a constant pattern in the pre-parturient period, however that pattern became variable in the post-partum period. The frequency of the ruminal pH lower than 5.5 increased markedly 3 and 4 days after parturition. We demonstrated the possible application of a radio transmission pH measurement system for the assessment and monitoring of the ruminal pH of cows. Our new system might contribute to accurate assessment and prevention of SARA.
机译:留置的瘤胃pH系统已用于连续记录瘤胃pH以评估奶牛的亚急性瘤胃酸中毒(SARA)。但是,该系统不允许现场应用。这项研究的目的是开发一种新的无线电传输pH测量系统,并评估其在连续评估瘤胃pH值以用于商业奶牛场的性能和实用性。无线电传输pH测量系统由一个无线pH传感器,一个数据测量接收器,一个中继单元和一台装有特殊软件的个人计算机组成。 pH传感器装在子弹形药丸中,该药丸还包裹着pH放大器电路,中央处理器(CPU)电路,射频(RF)电路和电池。连续记录2个月后,玻璃pH电极测量的平均变化为+0.20(n = 10),与标准pH溶液在pH值为4和pH 7时确认的值相比较。记录开始。当每10分钟连续发送一次测量结果时,内部电池的平均寿命为2.5个月(n = 10)。我们的新系统记录的瘤胃pH与瘤胃液的现场采样进行了比较。斑点采样的平均pH为6.36+或-0.55( n = 96),连续记录的平均pH为6.22+或-0.54( n = 96) 。连续记录和斑点采样之间有很好的相关性( r = 0.986, P <0.01)。我们还检查了我们的新pH系统是否能够检测出实验性诱导的奶牛瘤胃酸中毒并记录瘤胃pH值的长期变化。在饲喂引起酸中毒的日粮中,在早晨饲喂后的头2小时内,瘤胃的pH值显着下降,而在夜间饲喂后,瘤胃的pH值明显下降,并且许多pH呈脉冲状变化。奶牛的pH值在午夜时段最低,为5.3-5.2,第二天早上喂奶后恢复到正常值。在一只健康的围产期奶牛中,瘤胃pH的昼夜变化在产前期被观察为恒定模式,但是在产后期该模式变得可变。产后3天和4天,瘤胃pH值低于5.5的频率明显增加。我们展示了无线电传输pH测量系统在评估和监测奶牛瘤胃pH值方面的可能应用。我们的新系统可能有助于准确评估和预防SARA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号