Amperometric biosensors using Pseudomonas putida cells as a bioelement were developed for 2,4-dichloro phenoxy acetic acid (2,4-D). After the adaptation process of Pseudomonas putida to 2,4-D, cells were immobilized onto the screen printed graphite electrodes (SPG) as well as Clark oxygen probe by gelatin and glutaraldehyde. Optimum pH, temperature, and stability of the biosensor were investigated. Substrate specificities for various phenolic compounds were also searched. In repeatability studies, variation coefficients and standard deviations for both type of systems were calculated; SPG and Clark electrodes were calculated and results are given as a comparison of two systems. Finally, the biosensors were applied to 2,4-D determination in a real herbicide sample.
机译:开发了使用恶臭假单胞菌(Pseudomonas putida)细胞作为生物元素的安培生物传感器,用于2,4-二氯苯氧基乙酸(2,4-D)。在恶臭假单胞菌适应2,4-D的过程后,通过明胶和戊二醛将细胞固定在丝网印刷的石墨电极(SPG)以及Clark氧探针上。研究了生物传感器的最佳pH,温度和稳定性。还研究了各种酚类化合物的底物特异性。在重复性研究中,计算了两种类型系统的变异系数和标准偏差。计算了SPG和Clark电极,并给出了两个系统的比较结果。最后,将生物传感器应用于真实除草剂样品中的2,4-D测定。