首页> 外文期刊>Chemical research in toxicology >Ex vivo oxidation in tissue and plasma assays of hydroxyoctadecadienoates: Z,E/E,E stereoisomer ratios.
【24h】

Ex vivo oxidation in tissue and plasma assays of hydroxyoctadecadienoates: Z,E/E,E stereoisomer ratios.

机译:羟基十八碳二烯酸酯的组织和血浆测定中的离体氧化:Z,E / E,E立体异构体比率。

获取原文
获取原文并翻译 | 示例
       

摘要

The primary products from peroxidation of linoleate in biological tissues and fluids are the hydroperoxy octadecadienoates, and the products normally assayed, after reduction of the hydroperoxides, are the corresponding hydroxy octadecadienoates (HODEs). The HODEs are found in tissues and fluids as a mixture of Z,E and E,E stereoisomers. Two regioisomeric sets of Z,E and E,E stereoisomers are normally observed with substitution at the 9- and 13-positions of the 18-carbon chain. The Z,E/E,E product ratio has proved to be a useful means for assessing the reducing capacity of the medium undergoing peroxidation. The HODE Z,E/E,E product ratios previously reported for tissues such as liver and brain vary from 0.5 to 2.0, and plasma ratios are somewhat higher, between 2.0 and 3.0. The reported literature protocols for HODE assay in tissues involve homogenization, reduction with sodium borohydride in the presence of BHT, and ester hydrolysis with KOH to give the free HODEs. This is followed by either reverse-phase HPLC of the free acid HODEs or by conversion to TMS derivatives and GC-MS. When sodium borohydride is replaced in the protocol by triphenylphosphine, a gentler reducing agent, HODE Z,E/E,E product ratios are much higher, and lower total HODE levels of are found. It is proposed that inclusion of sodium borohydride in the isolation procedures leads to ex vivo reactions that are avoided if triphenylphosphine is used as the reducing agent. Modified protocols for HODE analyses (tissue and plasma methods #2) are described that should be used for assays of tissues and fluids.
机译:亚油酸酯在生物组织和体液中过氧化的主要产物是氢过氧十八碳二烯酸酯,在氢过氧化物还原后,通常测定的产物是相应的羟基十八碳二烯酸酯(HODEs)。 HODEs以Z,E和E,E立体异构体的混合物形式存在于组织和体液中。通常观察到两个区域异构的Z,E和E,E立体异构体在18碳链的9和13位有取代。已经证明Z,E / E,E产物比是评估经历过氧化的介质的还原能力的有用手段。先前报道的诸如肝脏和脑等组织的HODE Z,E / E,E产品比率在0.5到2.0之间变化,血浆比率在2.0到3.0之间更高。组织中HODE测定的已报道文献方案包括均质化,在BHT存在下用硼氢化钠还原以及用KOH酯水解以生成游离HODE。然后进行游离酸HODE的反相HPLC或转化为TMS衍生物和GC-MS。当方案中的硼氢化钠被三苯基膦替代时,还原剂更温和,HODE Z,E / E,E产物的比率要高得多,而总的HODE水平较低。提出在分离步骤中包含硼氢化钠会导致离体反应,如果将三苯基膦用作还原剂,则可以避免这种反应。描述了HODE分析的修改方案(组织和血浆方法#2),应用于组织和体液的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号