Preliminary Shielding Analysis for HCCB TBM Transport

机译:HCCB TBM运输的初步屏蔽分析

获取原文
获取原文并翻译 | 示例
           

摘要

A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future.
机译:本文对ITER辐照后的中国氦冷却陶瓷育种试验毯模块(HCCB TBM)从法国运回中国进行了初步屏蔽分析。运输过程中重点放在辐射安全性上。 MCNP / 4C为概念包装设计计算的剂量率满足了IAEA的有关剂量限制,即距含有低比活度III物质的包装表面3 m的剂量率应小于10 mSv / h。还研究了停机后剂量位置随时间的变化和时间演变。这将有助于在不久的将来制定HCCB TBM返回中国的详细运输计划。