The ITER neutron shielding blocks are located between the outer shell and the inner shell of the vacuum vessel to provide neutron shielding. Considering the combined loads acting on the shielding blocks during ITER plasma operation, the structure of the shielding blocks must be evaluated. Using the finite element method with ANSYS analysis software, static structural analysis is performed, including elastic analysis and limit analysis for one typical shielding block. The evaluated results based on RCC-MR code show that the structure of this shielding block can meet the design requirement.
机译:ITER中子屏蔽块位于真空容器的外壳和内壳之间,以提供中子屏蔽。考虑到ITER等离子运行期间作用在屏蔽块上的组合载荷,必须评估屏蔽块的结构。使用有限元方法和ANSYS分析软件进行静态结构分析,包括对一个典型屏蔽块的弹性分析和极限分析。基于RCC-MR代码的评估结果表明,该屏蔽块的结构可以满足设计要求。