首页> 外文期刊>Chemical Senses >High Test-Retest Reliability of the Extended Version of the 'Sniffin' Sticks' Test
【24h】

High Test-Retest Reliability of the Extended Version of the 'Sniffin' Sticks' Test

机译:扩展版本的“嗅探棒”测试的高度重测可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

The "Sniffin' Sticks" test kit is a validated and commonly used tool for assessment of olfactory function in subjects with normal sense of smell and in individuals with smell loss. That test incorporates subtests for odor threshold, discrimination, and identification. To gain higher subtest reproducibility, tests on odor discrimination and odor identification were extended using 32 instead of the usually applied 16 single trials each. In developing the extended Sniffin' Sticks test, a number of preliminary experiments were performed in 46 healthy, normosmic individuals 1) to evaluate intensity and familiarity of the additionally selected odors, 2) to select distractors for the discrimination and identification test, and 3) to evaluate the test-retest reliability of each subtest. Furthermore, the extended test was applied to 126 patients with olfactory loss and 71 normosmic individuals. Follow-up investigation could be performed in 69 controls within an average interval of 4 days. Results revealed significant differences between patients and healthy subjects. Estimated intensity and familiarity of the newly selected 16 items of the discrimination test did not differ significantly from the 16 standard items. Test-retest reliability was found to be r = 0.80 (odor discrimination), r = 0.88 (odor identification), and r = 0.92 (odor threshold). In conclusion, the extended test kit allows a precise evaluation of olfactory function, especially when different olfactory tasks are assessed using individual subtests. Furthermore, the high test-retest reliability of both the 16 and the 32-item tests allows the evaluation of even relatively small changes of olfactory function over time by means of either test.
机译:“嗅探棒”(Sniffin'Sticks)测试套件是一种经过验证的常用工具,可用于评估具有正常嗅觉的受试者和患有嗅觉丧失的个体的嗅觉功能。该测试包含有关气味阈值,辨别力和识别力的子测试。为了获得更高的子测试重现性,气味识别和气味识别测试使用32个扩展,而不是通常使用的每个16个单个测试。在开发扩展的“ Sniffin's Sticks测试”时,对46位健康的常态个体进行了许多初步实验:1)评估额外选择的气味的强度和熟悉度; 2)选择用于鉴别和鉴定测试的干扰物,以及3)评估每个子测试的重测可靠性。此外,扩展测试适用于126名嗅觉丧失患者和71名正常个体。可以在平均4天的间隔内对69个对照进行随访研究。结果显示患者与健康受试者之间存在显着差异。新选择的16个判别测试项目的估计强度和熟悉程度与16个标准项目没有显着差异。重测信度为r = 0.80(气味鉴别),r = 0.88(气味识别)和r = 0.92(气味阈值)。总之,扩展的测试套件可以对嗅觉功能进行精确评估,尤其是当使用单独的子测验评估不同的嗅觉任务时。此外,16和32项测试均具有很高的重试可靠性,因此可以通过任一测试来评估相对较小的嗅觉功能随时间的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号