BACKGROUND: The Afinion AS100 analyser is a small bench-top, multi-assay, point-of-care (POC) analyser that is able to measure glycated haemoglobin (HbA1c) and lipid levels. OBJECTIVE: To assess performance of the Afinion analyser compared with a reference laboratory test for the measurement of HbA1c and lipid levels. METHOD: The study involved men and women enrolled in a cross-sectional study, Sexual health, HIV infection and comorbidity with non-communicable diseases among Older Persons (SHIOP), which was conducted from February to May 2016. Whole blood was drawn aseptically by a trained study nurse into a serum separator gel tube and an ethylenediaminetetra-acetic acid (EDTA) tube. The EDTA whole blood was used to measure HbA1c levels, and serum to measure total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and triglyceride levels. Lin's correlation coefficient was used to assess the agreement between the Afinion and ABX Pentra 400 analysers for each marker. RESULTS: A total of 435 older individuals were included in the study. The proportion of HbAlc results that were correctly classified by the Afinion analyser was 92.2%. Bland-Altman analysis and linear regression analysis showed a very good agreement (correlation concordance 0.89) between the two analysers for the measurement of HbAlc. The two-way scatter plot for TC showed a substantial correlation (0.80). However, a total of 69 cholesterol results that were within the normal range on the Pentra were misclassified as abnormal on the Afinion. The readings obtained for HDL-C levels with the Afinion were shown to be slightly overestimated when compared with the Pentra. However, correlation for HDL-C on the two analysers was 0.93, indicating an almost perfect agreement. Seventy-four LDL-C results were erroneously classified as abnormal on the Afinion but were within the normal range on the Pentra, resulting in a substantial correlation of 0.75. An excellent agreement was observed between triglyceride measurements (0.99). CONCLUSION: This study supports the use of the Afinion AS100 analyser in POC testing for the measurement of HbAlc, triglycerides and HDL-C in a South African setting.
机译:背景:Afinion AS100分析仪是一款小型台式,多分析,即时点(POC)分析仪,能够测量糖化血红蛋白(HbA1c)和脂质水平。目的:为了评估Afinion分析仪的性能,并与用于测量HbA1c和血脂水平的参考实验室测试进行比较。方法:该研究涉及2016年2月至2016年5月进行的一项横断面研究,即性健康,HIV感染和老年人非传染性疾病合并症(SHIOP)的男性和女性。一名训练有素的研究护士将其插入血清分离器凝胶管和乙二胺四乙酸(EDTA)管中。 EDTA全血用于测量HbA1c水平,血清用于测量总胆固醇(TC),高密度脂蛋白胆固醇(HDL-C),低密度脂蛋白胆固醇(LDL-C)和甘油三酸酯水平。 Lin的相关系数用于评估Afinion和ABX Pentra 400分析仪之间每种标记的一致性。结果:总共435名老年人被纳入研究。由Afinion分析仪正确分类的HbAlc结果比例为92.2%。 Bland-Altman分析和线性回归分析表明,两种分析仪在HbAlc的测量中具有很好的一致性(相关一致性0.89)。 TC的双向散点图显示出显着的相关性(0.80)。但是,在Pentra正常范围内的总共69项胆固醇结果在Afinion上被误分类为异常。与Pentra相比,使用Afinion获得的HDL-C水平的读数显示有些高估。但是,两个分析仪上的HDL-C的相关性为0.93,表明几乎完美的一致性。在Afinion上将74个LDL-C结果错误地归类为异常,但在Pentra上却处于正常范围内,导致相关系数为0.75。在甘油三酸酯测量之间观察到极好的一致性(0.99)。结论:这项研究支持在南非POC测试中使用Afinion AS100分析仪来测量HbAlc,甘油三酸酯和HDL-C。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号