BLACK BAND" TESTING, SETTING THE neutral, checking interpole polarity, bar-to-bar testing-these and most other test procedures described in d-c machine literature are "diagnostic" (Figure 1). Their purpose is to search out defects-shorts and opens in the armature winding, improper field connections, or commutator problems.
机译:“黑带”测试,设置中性线,检查极间极性,条对条测试-这些以及其他在直流电机文献中描述的测试程序都是“诊断性的”(图1)。其目的是找出缺陷,短路和短路。电枢绕组开路,磁场连接不当或换向器出现问题。