首页> 外文期刊>Thin-Walled Structures >Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns
【24h】

Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns

机译:填充混凝土的双层蒙皮(SHS外部和CHS内部)钢管梁柱

获取原文
获取原文并翻译 | 示例

摘要

A series of tests on concrete-filled double skin steel tubular (CFDST) stub columns (14), beams (four) and beam-columns (12) were carried out. The specimens had square hollow section (SHS) as outer skin and circular hollow section (CHS) as inner skin. A mechanics model is developed in this paper for the CFDST stub columns, columns and beam-columns. A unified theory is described where a confinement factor (ξ) is introduced to describe the composite action between the steel tubes and the sandwiched concrete. The load versus axial strain relationship for CFDST stub columns is predicted. Simplified model is derived for section capacities of CFDST. The predicted beam-column strength is compared with that obtained in beam and beam-column tests. The load versus mid-span deflection relationship for CFDST beams and beam-columns is predicted. A simplified model is developed for calculating the member capacity of the CFDST beams. Simplified interaction curves are derived for CFDST beam-columns.
机译:对钢管混凝土短柱(CFDST)短柱(14),梁(四个)和梁柱(12)进行了一系列测试。标本具有方形空心截面(SHS)作为外皮和圆形空心截面(CHS)作为内皮。本文针对CFDST短柱,柱和梁柱建立了力学模型。描述了一个统一的理论,其中引入了限制因子(ξ)来描述钢管和夹层混凝土之间的复合作用。预测了CFDST短柱的载荷与轴向应变的关系。得出了CFDST的截面容量的简化模型。将预测的梁柱强度与在梁和梁柱试验中获得的强度进行比较。预测了CFDST梁和梁柱的荷载与跨距的挠度关系。开发了用于计算CFDST梁的构件承载力的简化模型。为CFDST梁柱导出了简化的相互作用曲线。