首页> 外文期刊>Thin-Walled Structures >Experimental testing of joints for seismic design of lightweight structures. Part 2: Bolted joints in straps
【24h】

Experimental testing of joints for seismic design of lightweight structures. Part 2: Bolted joints in straps

机译:轻型结构抗震设计的节点试验测试。第2部分:皮带中的螺栓连接

获取原文
获取原文并翻译 | 示例

摘要

An experimental testing campaign on tensile bolted joints between straps is reported. Two dominant failure modes are identified: (1) tilting, bearing and tearing of the sheets (TS) and (2) tilting, bearing and net-section failure (NSF). The analysis in terms of ductility and strength shows that bolted connections are less adequate than screwed connections (reported in Part 1 of this paper) for the seismic design of X-braced shear walls in lightweight structures. NSF joints are more ductile than TS joints in the sense that they undergo larger displacements before failure. However, if washers are not used, both types of connections fail before energy dissipation through yielding of the diagonal straps can occur. Some design recommendations to improve the seismic performance of bolted joints, including the use of washers, are given. The accuracy of Eurocode 3 formulas to predict the ultimate load is also analyzed.
机译:据报道,对皮带之间的拉伸螺栓连接进行了实验测试。确定了两种主要的失效模式:(1)纸张倾斜,承重和撕裂(TS),以及(2)倾斜,承重和净截面失效(NSF)。就延性和强度进行的分析表明,对于轻型结构中的X形剪力墙的抗震设计,螺栓连接不如螺栓连接(本文第1部分报道)足够。 NSF接头比TS接头更具延展性,因为它们在失效前会经历较大的位移。但是,如果不使用垫圈,则这两种类型的连接都会失败,然后才可能因对角带的屈服而导致能量耗散。提出了一些改善螺栓连接的抗震性能的设计建议,包括使用垫圈。还分析了Eurocode 3公式预测最终载荷的准确性。