首页> 外文期刊>Thin-Walled Structures >Analysis and design reliability of axially compressed members with high-strength cold-formed thin-walled steel
【24h】

Analysis and design reliability of axially compressed members with high-strength cold-formed thin-walled steel

机译:高强度冷弯薄壁钢轴压构件的分析与设计可靠性

获取原文
获取原文并翻译 | 示例

摘要

High-strength cold-formed thin-walled steel has been widely used in developed countries in the last several years. However, the application and popularization of the new materials in China is still very limited, and there are no related provisions in current design codes for reference in engineering practice. In this paper, considering the effects of the variations from material strength in structural members, geometrical parameters of sections, analysis methods for limit load-carrying capacity and external loadings, the second-order moment probability method was used for conducting the design reliability analysis of 550 MPa high-strength cold-formed thin-walled steel structures, from which the reasonable target reliability index, the corresponding resistance partial coefficient and the design strength values were discussed and proposed. Existing experimental data related have been collected and used to demonstrate the suitability and reasonability of the proposed results, which shows that, with reasonable determination of the design strength value of 550 MPa high-strength cold-formed thin-walled steel sections, the effective width-to-thickness ratio method considering coupling stability of plates recommended by "Technical Code of Cold-formed Thin-Walled Steel Structures (GB50018-2002)" can be efficiently used to estimate the load-carrying capacities of the axially compressed elements of high-strength cold-formed thin-walled steel structures, and well satisfy the target reliability index in structural design.
机译:最近几年,高强度冷弯薄壁钢已在发达国家广泛使用。但是,新材料在中国的应用和推广还很有限,目前的设计规范中没有相关规定可供工程实践参考。本文考虑了结构构件材料强度变化,型材几何参数,极限承载力和外部荷载分析方法的影响,采用二阶矩概率法对结构进行了设计可靠度分析。提出并提出了550 MPa高强度冷弯薄壁钢结构的合理目标可靠度指标,相应的电阻分系数和设计强度值。收集了相关的现有实验数据,并证明了所提出结果的适用性和合理性。结果表明,在合理确定550 MPa高强度冷弯薄壁型钢截面设计强度值的情况下,有效宽度“冷弯薄壁钢结构技术规范(GB50018-2002)”中推荐的考虑板的耦合稳定性的厚度比方法可以有效地估算高强度钢的轴向压缩元件的承载能力。强度高的冷弯薄壁钢结构,并很好地满足结构设计中的目标可靠性指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号