A total of 62 single shear bolted connection specimens were tested using transient state test method. The specimens of single shear bolted connections were fabricated by three different thicknesses of thin sheet steels. The tests were conducted at three different load levels of 25%, 50% and 75% of the failure load at ambient temperature. The tendency of the test strength reduction of the single shear bolted connections conducted using the transient state test method is generally similar to that for the steady state test method. However, it is shown that the transient state test results are always conservative compared with the steady state test results. Three main failure modes, namely the bearing, tear out and net section tension, were observed in the transient state tests. The failure modes of the specimens in transient state tests for the load level of 0.25 of the failure load at ambient temperature are generally consistent with those specimens in the steady state tests.
机译:使用瞬态测试方法测试了总共62个单剪螺栓连接样本。单剪螺栓连接的样品是由三种不同厚度的薄钢板制成的。在环境温度下,分别在失效负载的25%,50%和75%的三种不同负载水平下进行测试。使用瞬态测试方法进行的单剪切螺栓连接的测试强度降低的趋势通常与稳态测试方法相似。但是,可以看出,与稳态测试结果相比,瞬态测试结果始终是保守的。在瞬态测试中观察到三种主要的失效模式,即轴承,撕裂和净截面张力。在瞬态测试中,样品在环境温度下的载荷水平为0.25时的失效模式通常与稳态测试中的样品一致。