首页> 外文期刊>Thin-Walled Structures >Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns
【24h】

Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns

机译:钢管混凝土薄壁钢管柱盲板端板节点的结构性能

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the results of an experimental study on the structural behavior of blind bolted end plate connections between steel beams and concrete-filled thin-walled steel tubular (CFTST) columns under monotonic loading. The square tube in each CFTST column connection was fabricated by seam welding four pieces of lipped angle with nominal wall thickness 1.5 mm or 3 mm together. In order to enhance the stiffness of the connection, extensions are provided to the blind bolts to link the connection back into the concrete with the tube. The objective of this study is to develop a novel bolted moment connection which is easy to use in the thin-walled structures. The structural performance of the blind bolted connection is evaluated in terms of the failure modes, moment rotation relationship, connection rigidity and strain response of critical components. Some anchorage strengthening methods were proposed to enhance the strength and stiffness of the connection. The experimental results indicate that the proposed CFTST column connections behave in a semi-rigid and partial strength manner according to the EC3 specification, whilst its rotation capacity satisfies the ductility design requirements for earthquake-resistance in most aseismic region. Adopting reasonable connection measurement, the proposed blind bolted connection to the CFTST columns was a reliable and effective solution for low-layer and multilayer frame structures.
机译:本文介绍了在单调荷载下钢梁与混凝土薄壁钢管柱之间的盲孔螺栓端板连接结构性能的实验研究结果。每个CFTST立柱连接中的方管是通过将四个标称壁厚为1.5 mm或3 mm的卡角无缝焊接在一起而制成的。为了提高连接的刚度,在盲孔螺栓上设置了延伸部分,以通过管将连接重新连接回混凝土中。这项研究的目的是开发一种新颖的螺栓力矩连接,该连接易于在薄壁结构中使用。根据失效模式,力矩旋转关系,连接刚度和关键部件的应变响应来评估盲孔螺栓连接的结构性能。提出了一些锚固加固方法,以增强连接的强度和刚度。实验结果表明,根据EC3规范,建议的CFTST立柱连接具有半刚性和部分强度的方式,而其旋转能力满足大多数抗震地区的抗震延性设计要求。通过合理的连接测量,建议的到CFTST柱的盲孔螺栓连接是用于低层和多层框架结构的可靠且有效的解决方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号