To simplify the waste concrete recycling process, the authors have proposed several new kinds of structural members containing demolished concrete with a distinctly larger size than conventional recycled aggregates. Previous researches and applications have preliminarily verified the suitability of these new environment-friendly structural members. The objective of the presented research is to provide new test data to study the seismic performance and to evaluate the strength and ductility of the thin-walled circular steel tubular column filled with demolished concrete blocks (DCBs) and fresh concrete (FC). Fifteen specimens, including 10 columns filled with DCBs and FC and 5 reference columns filled with FC alone, were tested under combined constant axial compression and reversed cyclic lateral loadings. Test variables are: replacement ratio of DCBs, thickness of steel tube, and axial load ratio. Based on the concept of combined strength of new and old concrete in steel tube, some design codes are employed to predict the lateral strength of the specimens. Research findings indicate that: (1) the seismic performance of thin-walled circular steel tubular columns filled with DCBs and FC is similar to that of the reference columns filled with FC alone; (2) the lateral strength of the columns filled with DCBs and FC is slightly lower than that of the reference columns filled with FC alone; and (3) even though the diameter-to-thickness ratio is only 168, the ultimate drift ratio of such a specimen filled with DCBs and FC with an axial load ratio of 0.4 can reach 4%, showing good deformation capacity.
机译:为了简化废弃混凝土的回收过程,作者提出了几种新型结构构件,其中包含拆除后的混凝土,其尺寸明显大于传统的回收骨料。先前的研究和应用已初步验证了这些新型环保结构构件的适用性。本研究的目的是提供新的试验数据,以研究抗震性能,并评估填充有拆除的混凝土块(DCB)和新鲜混凝土(FC)的薄壁圆形钢管柱的强度和延性。在组合的恒定轴向压缩力和反向循环侧向荷载下测试了15个样品,包括10个装有DCB和FC的柱子和5个单独装有FC的参比柱子。测试变量为:DCB的更换率,钢管的厚度和轴向载荷率。基于钢管中新旧混凝土组合强度的概念,采用一些设计规范来预测试件的侧向强度。研究发现表明:(1)填充有DCB和FC的薄壁圆形钢管柱的抗震性能与仅填充FC的参考柱相似。 (2)填充DCB和FC的柱子的侧向强度略低于仅填充FC的参考柱子的侧向强度; (3)即使直径与厚度之比仅为168,这种装有轴向载荷比为0.4的DCBs和FC的试样的最终漂移率也可以达到4%,表现出良好的变形能力。

著录项

  • 来源
    《Thin-Walled Structures》 |2013年第5期|50-61|共12页
  • 作者单位

    State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou, Guangdong Province 510640, People's Republic of China;

    State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou, Guangdong Province 510640, People's Republic of China;

    State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou, Guangdong Province 510640, People's Republic of China;

    State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou, Guangdong Province 510640, People's Republic of China,School of Civil Engineering, Xi'an University of Architecture & Technology, Xi'an, Shanxi Province 710055, People's Republic of China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    thin-walled circular steel tube; demolished concrete block; column; seismic performance; cyclic testing; strength;