This paper aims to study the stress concentration factors (SCF) of thin-walled concrete-filled circular hollow section (CHS) T-, Y-, K-, and KT-joints subjected to axial tension loading. Experiment was performed to investigate the Hot Spot Stress distribution along the intersection of chord and brace. Eleven test specimens with self compacting concrete filled in the chord were tested. Test results indicate that the stress distribution is mainly determined by joint type, while the chord thickness has little effect on it. The stress concentration factors obtained from the test results were compared against predictions from some of the well-established existing equations for steel joints. Generally, the predictions from those equations are very conservative. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文旨在研究承受轴向拉力的薄壁混凝土圆空心截面(CHS)T型,Y型,K型和KT型接头的应力集中因子(SCF)。进行实验以研究沿弦和支撑的交点处的热点应力分布。测试了11个在弦中填充有自密实混凝土的试样。测试结果表明,应力分布主要由节理类型决定,而弦厚对节理影响不大。从测试结果中获得的应力集中因子与一些公认的现有钢接头方程式的预测值进行了比较。通常,从这些方程式得出的预测非常保守。 (C)2015 Elsevier Ltd.保留所有权利。