首页> 外文期刊>Thin-Walled Structures >Comparative study of square stirrup-confined concrete-filled steel tubular stub columns under axial loading
【24h】

Comparative study of square stirrup-confined concrete-filled steel tubular stub columns under axial loading

机译:方形箍筋约束钢管混凝土短柱在轴向荷载下的比较研究

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a comparative study and a 3D finite element (FE) model of square stirrup-confined concrete-filled steel tubular (stirrup-confined CFT) stub columns. The FE results agreed well with the experimental results. The results indicated that: (1) The ultimate load-bearing capacity of CFT stub columns with internal studs was no improvement; (2) All three forms of stirrup confinement effectively reduced local bucking of the steel tube, and the cross ties was optimal, followed by spiral stirrups; (3) With the same overall steel ratio, the behavior of the square stirrup-confined CFT stub columns was considerably higher than in the square CFT stub columns. (C) 2015 Published by Elsevier Ltd.
机译:本文介绍了方形箍筋约束的钢管混凝土(箍筋约束的CFT)短柱的比较研究和3D有限元(FE)模型。有限元结果与实验结果吻合良好。结果表明:(1)带有内部螺柱的CFT短柱的极限承载力没有改善; (2)三种形式的箍筋约束有效地减少了钢管的局部弯曲,并且交叉带是最佳的,其次是螺旋箍筋; (3)在相同的总钢比下,方形箍筋约束的CFT短管柱的性能明显高于方形CFT短管柱。 (C)2015年由Elsevier Ltd.出版