首页> 外文期刊>Thin-Walled Structures >Experimental analysis of built-up closed cold-formed steel columns with restrained thermal elongation under fire conditions
【24h】

Experimental analysis of built-up closed cold-formed steel columns with restrained thermal elongation under fire conditions

机译:火灾条件下热伸长受限的封闭式冷弯型钢组合柱的试验分析

获取原文
获取原文并翻译 | 示例
           

摘要

An experimental research on the fire behaviour of compressed cold-formed steel columns with closed built-up cross-sections and restrained thermal elongation is presented. Several parameters were assessed, including the influence of loading level, boundary conditions, restraint to thermal elongation imposed by the surrounding structure and cross-sectional shape. The investigation suggests that an increase in the non-dimensional axial restraint ratio and column load levels lead to a decrease in critical temperatures. Furthermore, the 350 degrees C critical temperature limit predicted in the EN 1993-1-3:2005 may be too simplistic and conservative for fire design of this type of columns. (C) 2016 Elsevier Ltd. All rights reserved.
机译:提出了封闭截面,热伸长受限的压缩冷弯型钢柱火灾行为的试验研究。评估了几个参数,包括载荷水平,边界条件,对周围结构施加的热伸长的限制以及横截面形状的影响。研究表明,无量纲轴向约束比和柱载荷水平的增加导致临界温度的降低。此外,EN 1993-1-3:2005中预测的350℃临界温度极限对于这种类型的色谱柱的防火设计而言可能过于简单和保守。 (C)2016 Elsevier Ltd.保留所有权利。