首页> 外文期刊>Thin-Walled Structures >Strength and stiffness of cold-formed steel purlins with sleeved and overlapped bolted connections
【24h】

Strength and stiffness of cold-formed steel purlins with sleeved and overlapped bolted connections

机译:带套筒和重叠螺栓连接的冷弯钢pur条的强度和刚度

获取原文
获取原文并翻译 | 示例
           

摘要

This paper aims to analyze the strength and stiffness of semi-continuous cold-formed steel purlins subjected to flexure. A series of nine cold-formed steel Z sections with sleeved and overlapped bolted connections were tested in bending. Results show that strength is often limited by a plastic mechanism failure, which reduces the web rigidity and induces an early development of local buckling in the compressed flange. In addition to the experiments, this paper presents a numerical and analytical study of the strength and stiffness of semi-continuous purlins, as well as, an analytical method to predict vertical displacement. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本文旨在分析受弯的半连续冷弯型钢pur条的强度和刚度。通过弯曲测试了一系列九个带有套筒和重叠螺栓连接的Z型钢冷弯型材。结果表明,强度通常受塑性机构破坏的限制,塑性破坏会降低腹板的刚度,并导致压缩法兰中局部屈曲的早期产生。除了实验之外,本文还对半连续pur条的强度和刚度进行了数值和分析研究,以及预测竖向位移的分析方法。 (C)2016 Elsevier Ltd.保留所有权利。