首页> 外文期刊>Thin-Walled Structures >Dune sand concrete-filled steel tubular (CFST) stub columns under axial compression: Experiments
【24h】

Dune sand concrete-filled steel tubular (CFST) stub columns under axial compression: Experiments

机译:轴向压缩下的沙丘填充钢管混凝土(CFST)短柱:实验

获取原文
获取原文并翻译 | 示例

摘要

The behaviour of dune sand concrete-filled steel tubular (CFST) stub columns under axial compression was experimentally investigated in this paper, where the nominal cube strength of concrete was 60 MPa. A total of 24 specimens including 20 dune sand CFST stub columns and 4 reference hollow steel tubular stub columns were tested. The effects of tube thickness, cross-sectional dimension and concrete infill on the behaviour of the composite stub columns were investigated. The results showed that, similar to conventional CFST stub columns, the tested dune sand CFST stub columns behaved in a ductile manner and displayed an outward buckling failure model with high compressive strength. It indicates that it is feasible to use dune sand to replace normal sand to fabricate CFST columns in regions close to deserts. Comparisons were made between the test results and the predicted ultimate strength using the existing codes AIJ (2008), AISC360-10 (2010), BS5400 (2005), DBJ/T1351-2010 (2010) and EC4 (2004). Generally, these codes are conservative but acceptable for predicting the ultimate strength of dune sand CFST stub columns.
机译:本文对沙丘钢管混凝土短柱的轴向受压性能进行了试验研究,其中混凝土的立方强度为60 MPa。总共测试了24个样本,包括20个沙丘CFST短管柱和4个参考空心钢管短管柱。研究了管厚,横截面尺寸和混凝土填充物对复合短柱性能的影响。结果表明,与常规CFST短柱类似,被测试的沙丘CFST短柱表现出延性,并表现出具有高抗压强度的向外屈曲破坏模型。这表明在靠近沙漠的地区,用沙丘砂代替普通砂在CFST柱上加工是可行的。使用现有规范AIJ(2008),AISC360-10(2010),BS5400(2005),DBJ / T1351-2010(2010)和EC4(2004)对测试结果与预测极限强度进行了比较。通常,这些代码是保守的,但是对于预测沙丘CFST短柱的极限强度是可以接受的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号