Concrete-filled double-skin steel tubes (CFDSTs) are comprised of two concentrically placed steel tubes and concrete core filled in the annulus between the two tubes. A number of studies have demonstrated the excellent structural performance of CFDSTs as load-bearing columns under various loading conditions, which have attracted lots of interests of engineers and researchers. Despite the increasing popularity of using CFDSTs as load-bearing structural columns, there is limited knowledge on blast resistant performance of CFDST columns particular under close-in explosion. In this paper, an experimental study was conducted to investigate the residual axial load-carrying capacity of CFDST columns after being subjected to close-in explosion. Field blast tests were firstly carried out on CFDST columns. Then, the blast-damaged columns were subjected to axial compression till failure under quasi-static condition in the laboratory to examine their residual axial load-carrying capacities. Seven half-scale CFDST column specimens were constructed and tested, of which one column serves as a reference column that was directly tested under axial compression to check the ultimate axial load-carrying capacity of CFDST columns without blast damage. The influences of design factors including charge weight, stand-off distance, charge orientation, and section hollow ratio on blast resistant performance of CFDST columns were quantitatively assessed based on the residual axial capacity index. It was found that under close-in blast loading CFDST columns showed localized cross-section denting with slight global deformation. The damaged columns can maintain up to 60% of its ultimate axial load-carrying capacity and exhibited good strength and ductility.
机译:混凝土双层钢管(CFDST)由两个同心放置的钢管和混凝土芯组成,填充在两个管之间的环形空间中。许多研究证明了CFDSTS在各种负载条件下作为承载柱的优异结构性能,这引起了工程师和研究人员的许多兴趣。尽管使用CFDSTS作为承载结构柱的普及程度越来越越来越普及,但在近爆裂时,CFDST柱的爆炸性能有限。在本文中,进行了实验研究,以研究CFDST柱后闭合爆炸后的残留轴向载荷容量。首先在CFDST柱上进行现场爆炸试验。然后,对爆破损伤的柱进行轴向压缩,直到实验室中的准静态条件下发生故障,以检查它们的残余轴向承载能力。构造和测试了七个半尺度CFDST柱样本,其中一列用作参考柱,该参考柱在轴向压缩下直接测试,以检查CFDST柱的最终轴向承载能力,无爆炸损坏。基于残余轴向容量指数,定量评估了电荷重量,脱落距离,电荷取向和截面中空比的设计因子的影响,对CFDST柱的爆炸性能进行了定量评估。结果发现,在近距离爆破时,CFDST柱显示局部横截面,具有轻微的全局变形。损坏的柱子可以保持其最终轴向承载能力的高达60%,并且具有良好的强度和延展性。

著录项

  • 来源
    《Thin-Walled Structures》 |2021年第8期|107976.1-107976.12|共12页
  • 作者单位

    Southeast Univ Sch Civil Engn Minist Educ Engn Res Ctr Safety & Protect Explos & Impact Nanjing 211189 Peoples R China;

    Southeast Univ Sch Civil Engn Minist Educ Engn Res Ctr Safety & Protect Explos & Impact Nanjing 211189 Peoples R China;

    Southeast Univ Sch Civil Engn Minist Educ Engn Res Ctr Safety & Protect Explos & Impact Nanjing 211189 Peoples R China;

    Southeast Univ Sch Civil Engn Minist Educ Engn Res Ctr Safety & Protect Explos & Impact Nanjing 211189 Peoples R China;

    Curtin Univ Sch Civil & Mech Engn Ctr Infrastruct Monitoring & Protect Perth WA 6102 Australia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    CFDST column; Close-in explosion; Field blast test; Residual axial capacity; Performance assessment;