首页> 外文期刊>Thin-Walled Structures >Design of screwed connections in cold-formed steels in shear
【24h】

Design of screwed connections in cold-formed steels in shear

机译:剪切中冷成型钢的螺纹连接设计

获取原文
获取原文并翻译 | 示例

摘要

Experiments on screwed connections in shear were carried out at the University of Sydney using 2 or 3 selfdrilling screws connecting high strength cold-formed steel sheets. Different types of screws and various thickness combinations were used in order to investigate the bearing and tilting failure behaviour of screwed connections. The results are compared against standards and specifications from Australia, USA and Europe. From the comparisons, revised design equations based on the Australian Standard/New Zealand AS/NZS 4600:2018 are proposed. The equations are verified using data from other international data sets of screwed connection experiments in shear. The data are used to calculate new capacity reduction factors, which are higher than the current factor in AS/NZS 4600:2018 for screwed connections in bearing and tilting. Based on the comparison, a revised capacity reduction factor is proposed.
机译:使用连接高强度冷成型钢板的悉尼大学进行剪切螺纹连接的实验。使用不同类型的螺钉和各种厚度组合,以研究螺纹连接的轴承和倾斜故障行为。结果与澳大利亚,美国和欧洲的标准和规格进行了比较。从比较,提出了基于澳大利亚标准/新西兰的修订设计方程/ NZS 4600:2018。使用来自剪切中的螺纹连接实验的其他国际数据集的数据进行验证。数据用于计算新的容量降低因子,其高于AS / NZS 4600:2018中的当前因子,用于轴承和倾斜的螺纹连接。基于比较,提出了修改的容量减少因子。