首页> 外文期刊>Thin-Walled Structures >Minor-axis flexural buckling behaviour and resistances of pin-ended S690 high strength steel welded I-section columns
【24h】

Minor-axis flexural buckling behaviour and resistances of pin-ended S690 high strength steel welded I-section columns

机译:偏角弯曲屈曲行为和销结束S690高强度钢焊接I型柱电阻

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The present paper reports comprehensive experimental and numerical studies of pin-ended S690 high strength steel welded I-section columns failing by flexural buckling about the minor principal axis. The testing programme was conducted on two S690 high strength steel welded I-sections, and included initial geometric imperfection measurements and ten pin-ended column tests. This was followed by a numerical modelling programme, where finite element models were firstly developed to replicate the test responses and then adopted to conduct parametric studies to generate further numerical data over a wide range of cross-section dimensions and member lengths. The obtained test and numerical data, together with the test data collected from previous literature, were analysed and employed to assess the accuracy of the relevant design rules, as given in the European code, American specification and Australian standard, for S690 high strength steel welded I-section columns failing by flexural buckling about the minor principal axis. The assessment results revealed that both the European code and Australian standard yield conservative resistance predictions for S690 high strength steel welded I-section columns failing by flexural buckling about the minor principal axis, while the American specification offers an overall satisfactory level of design accuracy, but with some over-predicted design flexural buckling resistances for those intermediate and long columns with relatively large member non-dimensional slendernesses. Finally, an improved design approach was proposed and shown to provide safe, accurate and consistent resistance predictions for S690 high strength steel welded I-section columns failing by flexural buckling about the minor principal axis.
机译:本文报告了识别尖端S690高强度钢焊接I型柱的综合实验和数值研究,通过弯曲弯曲围绕小主轴弯曲。测试程序是在两个S690高强度钢焊接I段进行的,包括初始几何不完全测量和十个销结束柱测试。这是一个数值建模程序,其中首先开发有限元模型以复制测试响应,然后采用参数化研究以在宽范围的横截面尺寸和构件长度上产生进一步的数值数据。分析了所获得的测试和数值数据以及从先前文献中收集的测试数据,并用于评估相关设计规则的准确性,如欧洲代码,美国规格和澳大利亚标准,适用于S690高强度钢焊接i-section列通过弯曲围绕小主轴而失效。评估结果表明,欧洲代码和澳大利亚标准的屈服保守阻力预测对小主轴弯曲屈曲的弯曲屈曲,而美国规范提供了整体令人满意的设计精度水平,但通过一些过度预测的设计弯曲屈曲,用于那些具有相对大的成员非尺寸纤维的那些中间和长柱。最后,提出了一种改进的设计方法,并显示为S690高强度钢焊接I型柱的安全,准确和一致的电阻预测,通过弯曲弯曲围绕小主轴弯曲。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号