首页> 外文期刊>Thin-Walled Structures >Cyclic tests of fully prefabricated concrete-filled double-skin steel tube/moment-resisting frames with beam-only-connected steel plate shear walls
【24h】

Cyclic tests of fully prefabricated concrete-filled double-skin steel tube/moment-resisting frames with beam-only-connected steel plate shear walls

机译:钢管混凝土全剪力混凝土预制双壁钢管/抗弯框架的循环试验

获取原文
获取原文并翻译 | 示例

摘要

This paper proposes a fully prefabricated concrete-filled double-skin steel tube/moment-resisting frame with beam-only connected steel plate shear walls system. To realize the fully prefabricated construction of such a system, high-strength bolts are used for the beam -to-column joints, the column-to-column joints and the frame-to-wall joints. To reduce the additional forces of the boundary columns that are derived from the tension force action of the buckled steel plate shear wall (SPSW), beam-only connected SPSWs are proposed for this system. To evaluate the seismic performance of the proposed system, cyclic tests on three 1/2-scaled specimens were conducted in this paper. The damage observation, failure mechanism, and hysteretic behaviour of the test specimens are investigated and compared. The results show that the beam-only-connected steel plate shear walls (BSWs) enhanced the lateral resistance, initial stiffness and ductility of the fully prefabricated concrete-filled double -skin steel tube/moment-resisting frames. The specimens with BSWs tolerated more than a 5% story drift ratio, which was larger than the value of the bare frame, which increased with increasing numbers of BSWs, and the increment between each specimen was approximately equal. A similar finding was also observed in the initial stiffness, lateral resistance and ductility ratio. Furthermore, theoretical formulas are developed to estimate the lateral resistance of the BSWs and the bolt connections between the frame and the BSWs, and these proposed formulas are validated by the test results.
机译:本文提出了一种完全预制的填充混凝土的双层钢管/抗弯框架,仅采用连接梁的钢板剪力墙系统。为了实现这种系统的完全预制结构,高强度螺栓用于梁到柱的连接,柱到柱的连接以及框架到墙的连接。为了减少由弯曲的钢板剪力墙(SPSW)的拉力作用引起的边界柱的附加力,为此系统提出了仅连接梁的SPSW。为了评估所提出系统的抗震性能,本文对三个1/2比例的样本进行了循环测试。研究并比较了试样的损伤观察,破坏机理和滞后行为。结果表明,仅连接梁的钢板剪力墙(BSW)增强了预制混凝土填充的双层钢管/抗弯框架的侧向阻力,初始刚度和延性。带有BSW的标本可以承受5%以上的故事漂移率,该值比裸框的值大,后者随BSW数量的增加而增加,并且每个标本之间的增量大致相等。在初始刚度,侧向阻力和延性比方面也观察到类似的发现。此外,还开发了理论公式来估算BSW的侧向阻力以及框架与BSW之间的螺栓连接,并通过测试结果验证了这些提议的公式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号