首页> 外文期刊>Thin-Walled Structures >Experimental investigation on wind uplift capacity of single span Z-purlins supporting standing seam roof systems
【24h】

Experimental investigation on wind uplift capacity of single span Z-purlins supporting standing seam roof systems

机译:单跨Z型supporting支撑立煤层顶板系统的风升力试验研究。

获取原文
获取原文并翻译 | 示例
       

摘要

A total of 20 specimens of single-span purlin roof assemblies considering uplift wind load were tested to investigate the structural behavior of cold-formed steel Z-purlins having the tension flange fastened to standing seam roof systems. The variables of the tests include the type of standing seam roof systems, purlin thickness, purlin height and location of sag rods. Failure modes and flexural strengths of Z-purlins with and without sag rods were obtained from the tests. The test results were also compared with the flexural strengths calculated according to the Chinese code and North American specification, respectively. Furthermore, full finite element models representing the test specimens were then developed and nonlinear analysis was performed. The test results were in good agreement with the finite element analyses in terms of failure loads, failure modes and load-displacement curves.
机译:总共测试了20个考虑提升风载荷的单跨pur条屋顶组合件的样本,以研究将张紧法兰固定在直立接缝屋顶系统上的冷弯型钢Z型pur条的结构性能。测试的变量包括直立接缝屋顶系统的类型,pur条厚度,pur条高度和下垂杆的位置。从测试中获得了带有和不带有下垂杆的Z pur条的破坏模式和抗弯强度。还分别将测试结果与根据中国规范和北美规范计算出的抗弯强度进行了比较。此外,然后开发了代表试样的完整有限元模型,并进行了非线性分析。测试结果在失效载荷,失效模式和载荷-位移曲线方面与有限元分析非常吻合。