The results and an analysis of an experiment that was run on a full-scale integral safety stand(FISS- VVER)are presented; the stand simulates a VVER-1000 reactor installation. The initial event was a break with 4/100 leakage of the coolant from the outlet plenum when the hydraulic tanks of the emergency core-cooling sys- tem(ECCS)were in operation and when the high-and the low-pressure systems for the emergency cooling of the core failed.
机译:给出了在全尺寸整体安全支架(FISS-VVER)上进行的实验的结果和分析。支架模拟VVER-1000反应堆的安装。最初的事件是,当紧急堆芯冷却系统(ECCS)的液压油箱处于运行状态以及用于冷却系统的高压和低压系统运行时,冷却液从出气室泄漏4/100泄漏。核心的紧急冷却失败。