首页> 外文期刊>The Structural Engineer >Seismic resistance of flush endplate connections
【24h】

Seismic resistance of flush endplate connections

机译:平端板连接的抗震性

获取原文
获取原文并翻译 | 示例
       

摘要

The application of semi-rigid flush endplate connections to the seismic design of steel frames is investigated experimentally. Two test series are described in which specific connection details are varied and the effects on stiffness, resistance and ductility observed. Cyclic loading conditions representative of earthquake structural response are employed in each test. The observed plastic response mode, resistance and stiffness are compared with those predicted by Eurocode 3. While specimen stiffness did not vary greatly between tests, large differences in ductility were observed. Although intended for monotonic loading conditons, the provisions of the design Code proved adequate in determining whether a ductile or brittle failure would occur, but seriously underpredicted the ultimate resistance of the specimens. Such conservatism, which was most evident in the more ductile specimens, has implications for earthquake-resistant column design in which an upper bound on connection strength is required.
机译:实验研究了半刚性齐平端板连接在钢框架抗震设计中的应用。描述了两个测试系列,其中改变了具体的连接细节,并观察了其对刚度,阻力和延展性的影响。在每个测试中采用代表地震结构响应的循环荷载条件。将观察到的塑性响应模式,阻力和刚度与欧洲规范3预测的结果进行了比较。尽管试验之间的试样刚度变化不大,但在延展性方面却观察到很大差异。尽管旨在用于单调加载条件,但设计规范的规定已被证明足以确定是否会发生延性或脆性破坏,但严重低估了样品的极限抗力。这种保守性在更易延展的标本中最明显,它对抗震柱设计有一定的影响,在抗震柱设计中,要求连接强度有上限。