摘要

In order to be able to CE Mark the fabricated structural steelwork that they produce, steelwork contractors are required to declare performance to the System 2+ level of assessment (as described in Annex V of the CPR). This requires them to undertake: 1. initial type-testing of the product 2. Factory Production Control (FPC), which will include 2.1 implementation of FPC system procedures 2.2 appointment of a responsible welding coordinator (RWC) 2.3 implementation of welding quality management system (WQMS) procedures 3. further testing of samples taken at the factory in accordance with the prescribed test plan
机译:为了能够对自己生产的预制结构钢结构进行CE标记,钢结构承包商必须声明其性能达到System 2+评估水平(如CPR附录V中所述)。这要求他们承担:1.产品的初始型式测试2.工厂生产控制(FPC),其中将包括2.1实施FPC系统程序2.2任命负责的焊接协调员(RWC)2.3实施焊接质量管理体系(WQMS)程序3.按照规定的测试计划进一步测试在工厂抽取的样品