Concrete technologists have used ultrasonic pulse velocity test for decades to evaluate the properties of concrete. However, the presented research work focuses on the use of ultrasonic pulse velocity test to study the degradation in steel-concrete bond subjected to increasing loading. A detailed experimental investigation was conducted by testing five identical beam specimens under increasing loading. The loading was increased from zero till failure in equal increments. From the experimentation, it was found that as the reinforced concrete beams were stressed from control unloaded condition till complete failure, the propagating ultrasonic wave velocity reduced. This reduction in wave velocity is attributed to the initiation, development, and propagation of internal cracking in the concrete surrounding the steel reinforcement. Using both direct and semidirect methods of testing, results of reduction in wave velocity with evidence of internal cracking at steel-concrete interface are presented. From the presented results and discussion, it can be concluded that the UPV test method can be successfully employed to identify zones of poor bonding along the length of reinforced concrete beam. The information gathered by such testing can be used by engineers for localizing repairs thereby leading to saving of time, labor and cost of repairs. Furthermore, the implementation strategy along with real-world challenges associated with the application of the proposed technique and area of future development have also been presented.
机译:混凝土技术人员数十年来一直使用超声波脉冲速度测试来评估混凝土的性能。但是,目前的研究工作集中在使用超声波脉冲速度测试来研究钢-混凝土粘结在载荷增加时的降解。通过在增加的载荷下测试五个相同的梁样本进行了详细的实验研究。载荷以相同的增量从零增加到失效。从实验中可以发现,随着钢筋混凝土梁从控制卸载状态受力直至完全破坏,传播的超声波速度降低。波速的降低归因于钢筋周围的混凝土内部裂纹的产生,发展和传播。使用直接和半直接测试方法,给出了波速降低的结果,并给出了钢-混凝土界面内部开裂的证据。从给出的结果和讨论中可以得出结论,UPV测试方法可以成功地用于识别沿钢筋混凝土梁长度粘结不良的区域。通过这种测试收集的信息可以被工程师用于本地化维修,从而节省了时间,人工和维修成本。此外,还提出了实施策略以及与所提出的技术的应用和未来发展领域相关的现实挑战。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号