This paper includes a presentation of a shear test database that contains 278 tests conducted on reinforced concrete beams with vertical stirrups and no horizontal skin reinforcement. These beams are commonly referred to as non-slender beams since they were tested using loading arrangements that created shear span-to-depth ratios a/d < 2.4. In an effort to arrive at a database that can be used for the purposes of evaluating the accuracy and conservativeness of design provisions, several control and filtering criteria were applied. After this process, 178 beams remained in the evaluation database. The analyses conducted using this database indicated that the application of the strut-and-tie models (STM) of Eurocode 2 (EC2) to non-slender beams with stirrups is unconservative, i.e. the database analyses yielded results that were above the desired 5 % fractile. Almost all unconservative strength estimations were obtained for test specimens containing large numbers of stirrups. Conversely, statistical evaluations showed that the FIP Recommendations model for beams with point loads near supports is conservative.
机译:本文包括一个剪切试验数据库的介绍,该数据库包含278个试验,这些试验是在带有垂直箍筋而没有水平蒙皮的钢筋混凝土梁上进行的。这些梁通常被称为非细长梁,因为它们是使用产生剪切跨度与深度之比a / d <2.4的载荷布置进行测试的。为了获得可用于评估设计规定的准确性和保守性的数据库,应用了一些控制和过滤标准。在此过程之后,评估数据库中保留了178束。使用该数据库进行的分析表明,将Eurocode 2(EC2)的拉杆-拉杆模型(STM)应用于带有箍筋的非细长梁是不保守的,即,数据库分析得出的结果高于所需的5%。易碎。对于包含大量箍筋的试样,几乎获得了所有非保守强度估计。相反,统计评估表明,点支撑附近点荷载的梁的FIP建议模型是保守的。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号