首页> 外文期刊>Soil Dynamics and Earthquake Engineering >Updated liquefaction potential analysis eliminates foundation retrofitting of two critical structures
【24h】

Updated liquefaction potential analysis eliminates foundation retrofitting of two critical structures

机译:更新的液化潜力分析消除了两个关键结构的基础改造

获取原文
获取原文并翻译 | 示例
           

摘要

Developments in geotechnical engineering after 1970 prompted the foundations of three large nuclear material processing buildings in 1994. Concerns were raised because the subsurface conditions beneath them contain a Miocene-age clayey sand stratum with very low standard penetration resistance values. A preliminary liquefaction potential evaluation based on Seed et al. [The influence of SPT procedures in soil liquefaction resistance evaluation. Report no. UCB/EERC-84/15, October 1984] empirical procedures for Holocene-age data showed that based on the low blowcount the formation was liquefiable, and that foundation retrofitting was in order.
机译:1970年后岩土工程的发展促使1994年建立了三座大型核材料加工大楼。人们之所以担心,是因为其地下条件包含中新世时代的黏土砂岩地层,其标准抗渗性值非常低。基于Seed等人的初步液化潜力评估。 [SPT程序对土壤液化阻力评估的影响。报告编号[UCB / EERC-84 / 15,1984年10月]全新世时代数据的经验程序表明,基于低爆破次数,地层是可液化的,基础改造是有序的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号