首页> 外文期刊>Scanning >Clinical efficiency and reusability of the reciprocating nickel–titanium instruments according to the root canal anatomy
【24h】

Clinical efficiency and reusability of the reciprocating nickel–titanium instruments according to the root canal anatomy

机译:根据根管解剖结构的往复式镍钛器械的临床效率和可重复使用性

获取原文
获取原文并翻译 | 示例
       

摘要

The application of the single-file technique using the reciprocating motion is gaining concern in root canal preparation. The purpose of this research is to compare the efficiency of the reciprocating motion-employing files (RECIPROC and WaveOne) by measuring the working time for complete canal shaping, and to evaluate their reusability under scanning examinations. One hundred curved root canals of the extracted molars were used. The working length was determined and the glide path was confirmed using a #15 K-file. Canals shaping was completed to the length either with RECIPROC R25 file (n = 50), or with WaveOne Primary file (n = 50). The time taken for the file to reach the working length was also measured. Each file was repeatedly used in a maximum of 10 canals for comparing the change of the efficiency (shaping time) according to the working length, canal curvature, and number of file re-use. The deformations or surface defects of the files after the in vitro use were observed using a scanning electron microscope (SEM). There was no difference under the SEM between the 2 file groups with no initiation of micro-cracks until they were re-used up to 5 canals. WaveOne Primary file showed significantly shorter working time than RECIPROC R25 (p < 0.05). There was a statistically significant correlation between the working time and three variables. As the working length and the curvature of the canal increased, the shaping time was increased in both file systems. Reusability of these reciprocating instruments might be maximum 5 canals with minimal surface deformations. SCANNING 36:246–251, 2014. © 2013 Wiley Periodicals, Inc.
机译:使用往复运动的单锉刀技术的应用正在引起根管准备的关注。这项研究的目的是通过测量完成根管成形的工作时间来比较往复运动使用锉刀(RECIPROC和WaveOne)的效率,并在扫描检查中评估其可重复使用性。使用了一百颗弯曲的磨牙根管。确定工作长度,并使用#15 K锉确认滑行路径。使用RECIPROC R25文件(n = 50)或使用WaveOne Primary文件(n = 50),完成运河整形。还测量了锉刀达到工作长度所需的时间。每个锉刀最多可重复使用10个牙槽,以根据工作长度,牙槽曲率和锉刀重复使用次数比较效率(成形时间)的变化。使用扫描电子显微镜(SEM)观察体外使用后锉刀的变形或表面缺陷。在SEM下,两个文件组之间没有差异,没有微裂纹的产生,直到它们被重复使用至5条运河为止。 WaveOne Primary文件显示的工作时间比RECIPROC R25显着缩短(p(<0.05)。工作时间和三个变量之间存在统计上的显着相关性。随着工作长度和根管弯曲度的增加,两种锉刀系统的成形时间都增加了。这些往复式器械的可重复使用性最大为5条运河,而表面变形最小。扫描36:246–251,2014年。©2013 Wiley Periodicals,Inc.

著录项

  • 来源
    《Scanning》 |2014年第2期|1-6|共6页
  • 作者单位

    Department of Conservative Dentistry School of Dentistry Dental Research Institute Seoul National University Seoul Korea;

    Department of Pediatric Dentistry School of Dentistry Dental Research Institute Seoul National University Seoul Korea;

    Department of Conservative Dentistry School of Dentistry Dental Research Institute Seoul National University Seoul Korea;

    Department of Conservative Dentistry School of Dentistry Dental Research Institute Seoul National University Seoul Korea;

    Department of Conservative Dentistry School of Dentistry Daejeon Hospital WonKwang University Daejeon Korea;

    Department of Conservative Dentistry School of Dentistry Pusan National University Yangsan Korea;

    Department of Conservative Dentistry School of Dentistry Dental Research Institute Seoul National University Seoul Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    preparation time; canal curvature; working length; efficiency; reciprocating motion; reusability;

    机译:准备时间;曲率;工作长度;效率;往复运动;可重复使用性;
  • 入库时间 2022-08-18 01:37:42

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号