首页> 外文期刊>Russian electrical engineering >Selection of Permissible Current Loads of Power Cables Located in Cable Channels Taking into Account Losses in the Protective Metal Screens
【24h】

Selection of Permissible Current Loads of Power Cables Located in Cable Channels Taking into Account Losses in the Protective Metal Screens

机译:考虑到金属防护屏中的损耗,选择位于电缆通道中的电力电缆的允许电流负载

获取原文
获取原文并翻译 | 示例
           

摘要

A mathematical model of a complex process of heat transfer in a cable channel under conditions of natural convection is proposed. The influence of the metal protective screens on the operating temperature of cable lines is estimated, and the carrying capacities at the different section of the screens are calculated.
机译:提出了自然对流条件下电缆通道传热复杂过程的数学模型。估计金属保护屏对电缆线的工作温度的影响,并计算屏蔽屏不同部分的承载能力。