A very useful observation made by Professor Andrei Tugulea in mid 1980s allowed a new paradigm considering active and reactive power flow interpretation in three-phase circuits comprising at the same time nonlinear and unbalanced components. The article is intended to provide a deeper analysis, from this theory perspective, of a three-phase circuit with zero impedance neutral, which presents two different nonlinear and distorting loads powered through a supposedly balanced line. Symmetry, non-symmetry and residual (distortion) active and reactive powers are the appropriate quantity concepts defined by this theory capable to successfully take into account the nonlinearity and unbalance effects on active and reactive power circulation. Associated to these quantities, three normalized coefficients were introduced to allow a more direct depiction of the phenomena, namely symmetry, non-symmetry and distortion power factors. Original formulation of the theory was made for two balanced linear loads and a single unbalanced distorting one. The present work now considers a single balanced linear load (the power line) and two unbalanced nonlinear (distorting) loads, in a three-phase circuit with zero impedance neutral. Through PSpice simulation of various parameter circuits, all the possible instances regarding active and reactive powers flow directions are put demonstrated. To conclude, the obtained results are presented and interpreted.
机译:Andrei Tugulea教授在1980年代中期所做的非常有用的观察,使得新模型可以考虑同时包含非线性和不平衡分量的三相电路中的有功和无功潮流解释。从该理论的角度出发,本文旨在对零阻抗中性点的三相电路进行更深入的分析,该电路呈现出两个不同的非线性负载和失真负载,这些负载通过假定的平衡线路供电。对称,非对称和剩余(失真)有功功率和无功功率是该理论定义的适当数量概念,能够成功地考虑非线性和不平衡对有功功率和无功功率循环的影响。与这些量相关联,引入了三个归一化系数以更直接地描述现象,即对称,非对称和失真功率因数。该理论的原始表述是针对两个平衡的线性载荷和一个不平衡的扭曲载荷。现在,在零阻抗中性线的三相电路中,本工作现在考虑单个平衡线性负载(电源线)和两个不平衡非线性(失真)负载。通过各种参数电路的PSpice仿真,论证了所有关于有功和无功功率流向的可能实例。最后,介绍并解释了获得的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号