首页> 外文期刊>Reactive & Functional Polymers >Synthesis and study of copolymer of vinylferrocene, acrylamide and 2-(diethylamino)ethyl methacrylate as a polymeric mediator for electrochemical biosensors
【24h】

Synthesis and study of copolymer of vinylferrocene, acrylamide and 2-(diethylamino)ethyl methacrylate as a polymeric mediator for electrochemical biosensors

机译:乙烯基二茂铁,丙烯酰胺和甲基丙烯酸2-(二乙氨基)乙酯作为电化学生物传感器聚合物介体的共聚物的合成与研究

获取原文
获取原文并翻译 | 示例
           

摘要

Copolymer of vinylferrocene, acrylamide and 2-(diethylamino)ethyl methacrylate was synthesized by free-radical polymerization. Proton nuclear magnetic resonance and inductively coupled plasma-optical emission spectroscopy confirmed successful incorporation of ferrocene moieties in the copolymer. The effect of monomer feed ratio on copolymer molecular weight was studied and it was found that the increase in 2-(diethylamino)ethyl methacrylate fraction in the monomer feed facilitated incorporation of vinylferrocene and led to decrease in copolymer molecular weight. The synthetic process was scaled up in a pilot plant and an ultrafiltration method was developed to reduce residual levels of each monomer below 0.1% w/w. The copolymer displayed reversible redox electrochemical characteristics of the ferrocene moieties and mediation of glucose oxidation with enzyme flavin adenine dinucleotide-glucose dehydrogenase in phosphate buffered saline. A diffusion coefficient of 3.36 × 10~(-7) cm~2/s for the dissolved polymeric mediator was estimated from Randles-Sevcik analysis. The copolymer and the enzyme were mixed with water-based carbon ink and then screen-printed to form working electrodes. These biosensors established equilibrium current responses in less than 3 min following step changes of glucose concentration within the clinically relevant range of 8-735 mg/dL when exposed to a continuous flow of blood at 15 μL/min. The calibration plot of three biosensors aligned closely to a quadratic regression line (R square 0.9909) suggesting reasonable sensor measurement reproducibility and low levels of ferrocene leaching out of the polymeric mediator during the 7.5 h test period. A Michaelis constant for the sensor was estimated at 655 mg/dL.
机译:通过自由基聚合反应合成了乙烯基二茂铁,丙烯酰胺和甲基丙烯酸2-(二乙氨基)乙酯的共聚物。质子核磁共振和电感耦合等离子体发射光谱证实了在共聚物中成功地掺入了二茂铁部分。研究了单体进料比对共聚物分子量的影响,发现单体进料中甲基丙烯酸2-(二乙氨基)乙基甲基酯分数的增加促进乙烯基二茂铁的掺入并导致共聚物分子量的降低。在中试工厂中扩大了合成工艺,并开发了超滤方法以将每种单体的残留量降低至0.1%w / w以下。该共聚物显示出二茂铁部分的可逆氧化还原电化学特性,并在磷酸盐缓冲液中用黄素腺嘌呤二核苷酸-葡萄糖脱氢酶介导葡萄糖氧化。根据Randles-Sevcik分析,溶解的聚合物介体的扩散系数为3.36×10〜(-7)cm〜2 / s。将共聚物和酶与水基碳墨水混合,然后丝网印刷以形成工作电极。当暴露于15μL/ min的连续血流中时,在临床相关的8-735 mg / dL范围内的葡萄糖浓度阶跃变化之后,这些生物传感器在不到3分钟的时间内即可建立平衡电流响应。三个生物传感器的校准图紧密接近二次回归线(R平方0.9909),表明在7.5小时的测试期间,合理的传感器测量重现性和低水平的二茂铁从聚合物介体中浸出。传感器的米氏常数估计为655 mg / dL。

著录项

  • 来源
    《Reactive & Functional Polymers》 |2010年第10期|p.715-725|共11页
  • 作者单位

    LifeScan Scotland Limited, A Johnson & Johnson Company, Business Park North, Inverness IV2 3ED, United Kingdom;

    rnLifeScan Scotland Limited, A Johnson & Johnson Company, Business Park North, Inverness IV2 3ED, United Kingdom;

    rnLifeScan Scotland Limited, A Johnson & Johnson Company, Business Park North, Inverness IV2 3ED, United Kingdom;

    rnLifeScan Scotland Limited, A Johnson & Johnson Company, Business Park North, Inverness IV2 3ED, United Kingdom;

    rnLifeScan Scotland Limited, A Johnson & Johnson Company, Business Park North, Inverness IV2 3ED, United Kingdom;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    polymeric mediator; free-radical polymerization; ferrocene; electrochemical biosensors; blood glucose monitoring;

    机译:聚合物介体;自由基聚合;二茂铁电化学生物传感器血糖监测;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号