摘要

HSA immobilized poly(2-hydroxyethylmethacrylate), HSA-P[HEMA], cryogel monolith was examined as an alternative sorbent to be used in hemoperfusion columns for bilirubin removal from serum. The cryogel monolith synthesis was performed by free radical polymerization using MBAA as crosslinker, APS and TEMED as redox pair. Cyanogen bromide (CNBr) was used as a matrix-activating agent for the preparation of immobilized cryogels. Control cryogel monolith, P[HEMA], and HSA-P[HEMA] were characterized by swelling test, SEM images, porosity and surface area measurements, and blood compatibility tests. Activation and immobilization processes were optimized. The removal of bilirubin from plasma samples overloaded with bilirubin was performed using P[HEMA] cryogel monoliths containing different amounts of immobilized HSA in continuous mode. Several factors affecting adsorption capacity of the matrix such as incubation time, HSA concentration, bilirubin concentration in plasma and temperature were analysed. The maximum bilirubin removal from plasma was 25.4 mg/g at 37.5 degrees C. The desorption agent was 0.1 M NaOH and 1.0 M NaCl containing solution. The reusability was tested for 10 consecutive adsorption-desorption cycles. The adsorption isotherm models and kinetics of process were also studied. (C) 2015 Elsevier B.V. All rights reserved.
机译:检验了HSA固定的聚甲基丙烯酸2-羟乙酯,HSA-P [HEMA]冷冻凝胶整体料作为可用于血液灌流柱中从血清中去除胆红素的替代吸附剂。使用MBAA作为交联剂,APS和TEMED作为氧化还原对,通过自由基聚合进行冷冻凝胶整体成型。溴化氰(CNBr)被用作基质固定剂,用于制备固定的冷冻凝胶。对照冷冻凝胶整料,P [HEMA]和HSA-P [HEMA]通过溶胀试验,SEM图像,孔隙率和表面积测量以及血液相容性试验来表征。激活和固定过程进行了优化。使用含有不同量的固定化HSA的P [HEMA]冷冻凝胶整料,以连续模式从富含胆红素的血浆样品中去除胆红素。分析了影响基质吸附能力的几个因素,如孵育时间,HSA浓度,血浆中胆红素浓度和温度。在37.5摄氏度下从血浆中去除的最大胆红素为25.4 mg / g。解吸剂为0.1 M NaOH和1.0 M含NaCl的溶液。测试了10个连续的吸附-解吸循环的可重复使用性。还研究了吸附等温线模型和过程动力学。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号