Cytec's ammonia storage tank was last inspected in 1989, and based on internal requirements, would have been due for an internal inspection in 1999. Cytec has only one atmospheric ammonia storage tank. Inspecting this single tank would require solving significant logistical problems to avoid major business disruptions to the downstream operating units. Additionally, we wished to avoid the cost to decommission and clean, dispose of the wastes generated, inspect, and re-commission the tank. Based on prior inspection reports and a risk-based inspection documented by Capstone Engineering, the tank has been approved for at least five more years of service without an internal inspection. Within five years, an acoustic emission study will be conducted to insure that no audible defects can be found.
机译:Cytec的氨气储罐上一次检查是在1989年,根据内部要求,本应在1999年进行内部检查。Cytec仅有一个大气压氨气储罐。检查单个储罐将需要解决重大的物流问题,以避免对下游运营单位造成重大业务中断。此外,我们希望避免退役和清洁,处置产生的废物,检查和重新调试油箱的成本。根据先前的检查报告和Capstone Engineering记录的基于风险的检查,该储罐已被批准至少再使用五年,而无需内部检查。在五年内,将进行声发射研究,以确保不会发现可听见的缺陷。