LNG spills on land are most likely to happen in dike/impoundment areas, introducing the need to consider effects of dike/impoundment walls on vapor holdup and dispersion. The DEGADIS and FEM3A models are approved for determination of vapor cloud exclusion zones in 49 CFR 193, but DEGADIS is limited to prediction of dispersion from area sources over flat, obstacle-free terrain and is therefore not directly applicable to spills in dike/impoundment areas. However, FEM3A, which is a computational fluid dynamics (CFD) model, is directly applicable. Before FEM3A was approved, ad hoc methods were widely used to determine input conditions for DEGADIS to estimate dispersion downwind of a dike system for such releases. Vapor holdup and mixing with air in a dike system have been studied in wind tunnel and field experiments, and the fallacy of using an overly simplistic estimation of the time and rate of vapor cloud overflow has been demonstrated. In some cases, these ad hoc methods have resulted in exclusion zone determinations that do not provide for public safety as intended by 49 CFR 193. This paper summarizes the current state of knowledge about this important vapor dispersion scenario, including key experimental data that address the question. Applications of FEM3A to determine exclusion zones for a hypothetical spill within a typical dike/tank configuration, as well as a shortcut use of FEM3A to describe vapor overflow from the same impoundment for use as input information for DEGADIS simulation of the dispersion downwind from the dike, are illustrated.
机译:液化天然气在陆地上的泄漏最有可能发生在堤坝/蓄水区,这导致需要考虑堤坝/蓄水墙对蒸气滞留和扩散的影响。 DEGADIS和FEM3A模型已批准用于确定49 CFR 193中的蒸气云排除区域,但DEGADIS仅限于预测来自平坦,无障碍地形的区域源的扩散,因此不适用于堤坝/蓄水区的泄漏。但是,作为计算流体动力学(CFD)模型的FEM3A可直接应用。在FEM3A批准之前,特设方法被广泛用于确定DEGADIS的输入条件,以评估堤坝系统在此类释放时顺风方向的弥散。在风洞和野外实验中研究了堤坝系统中的蒸气滞留和与空气的混合,并且证明了使用过于简单的蒸气云溢出时间和速率估算的谬误。在某些情况下,这些特殊方法导致无法根据49 CFR 193的规定确定禁区,从而无法确保公共安全。本文总结了有关这一重要蒸气扩散方案的当前知识状态,包括解决以下问题的关键实验数据:题。应用FEM3A确定典型堤防/储罐配置中的假设溢漏的隔离区域,以及FEM3A的捷径使用来描述来自同一蓄水池的蒸汽溢流,以用作DEGADIS模拟堤防顺风的输入信息,如图所示。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号