Many flammable products are stored in large tanks at atmospheric pressure. Ignition of a hydrocarbon-air mixture in such tanks can lead to an explosion and cause lethal casualties or damage the surrounding facilities and buildings. To apprehend this, safety distances for humans, structures, and equipments need to be defined. Several simple methodologies have been set up to estimate safety distances in case of an atmospheric storage tank explosion. This third and last article concerning fixed roof atmospheric storage tank explosions focuses on numerical modeling, including gas explosion and structural response simulations. Three-dimensional gas explosion simulations using the CFD code FLACS have been performed to define a typical pressure load profile to apply on the inner side of the tank shell. Then, the structural response of the tank (deformation and displacement), under the loading conditions previously obtained, has been computed with LS-DYNA. Consequently, the findings question some of the assumptions used in analytical methods described previously. The specific input data needed to obtain a reasonably conservative estimation of the safety distances have been identified.
机译:许多易燃产品在大气压下存储在大罐中。在此类储罐中点燃碳氢化合物-空气混合物会导致爆炸并造成致命的人员伤亡或损坏周围的设施和建筑物。为此,需要定义人员,建筑物和设备的安全距离。已经建立了几种简单的方法来估算大气储罐爆炸时的安全距离。关于固定屋顶大气储罐爆炸的第三篇也是最后一篇文章着重于数值模型,包括气体爆炸和结构响应模拟。已经执行了使用CFD代码FLACS的三维气体爆炸模拟,以定义要施加在罐壳内侧的典型压力载荷曲线。然后,使用LS-DYNA计算了先前获得的载荷条件下储罐的结构响应(变形和位移)。因此,调查结果质疑了上述分析方法中使用的一些假设。已经确定了获得对安全距离进行合理保守估计所需的特定输入数据。

著录项

  • 来源
    《Process safety progress》 |2012年第3期|p.230-239|共10页
  • 作者

    Jerome Taveau; Benoit Moras;

  • 作者单位

    Institut de Radioprotection et de Surete Nucleaire, IRSN/DSU/SERIC/BEXI, 31, avenue de la Division Leclerc, 92 260 FONTENAY AUX ROSES cedex, France;

    Institut de Radioprotection et de Surete Nucleaire, IRSN/DSU/SERIC/BEXI, 31, avenue de la Division Leclerc, 92 260 FONTENAY AUX ROSES cedex, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    atmospheric storage tanks; fixed roof explosion; modeling; CFD; FLACS; LS-DYNA;