Structural characteristics of standard steel office buildings are investigated. Buildings are designed in two types of lateral resisting systems, which are space frame system (SFS) and perimeter frame system (PFS). Moment resisting connections are ' used in most of beam-column connections in SFS, where the columns are typically square hollow structural sections subject to bi-axiai bending moment under lateral forces. Contrarily, the moment resisting connections are limitedly used in the perimeter frames in PFS, where the columns are I-shaped sections and simple connections are used for beams connecting perpendicular to the lateral frames. Steel quantity is minimized under allowable stress design constraints. The design variables are the section sizes. It is found that the total steel quantity and welding length of PFS are smaller than those of SFS in four, seven and ten-story standard office buildings.%本研究では,鋼構造事務所建物の耐震架構配置に着目し,ほぼ全ての柱梁接合部を剛接合として全体を耐震架構とする設計(全体型)と外周に耐震架構を限定する設計(集約型)の構造性状を比較した。我国で一般的に設計される全体型の建物は,諸外国での集約型建物よりも鋼材量が多くなる可能性がある。検討対象は標準的な7階建建物とし,桁行方向(X方向)はラーメン構造,張間方向(Y方向)はブレース架構(全体型ではブレース架構とロングスパン梁を含むラーメン架構)である。全体型では柱を角形鋼管,集約型ではH形鋼とした。両型式の建物の骨組に対して,部材断面寸法を設計変数とし,許容応力度設計の条件を満足させることを制約条件とした鋼材量最小化を行った。得られた断面寸法を規格寸法に収斂させ,優良設計解を得た。両型式の優良設計解同士を比較して,耐震架構配置が鋼構造事務所建物の構造性状に及ぼす影響を比較分析した。最適化を用いたことにより,異なる耐震架構配置の設計解の比較において客観性を確保できた。また,設計を決定づける支配的な制約条件が分析できた。本研究で,得られた知見は以下の通りである。