A simple method of analysis is presented to determine the influence of single shear walls (SSW) on the degree of coupling DoC and on the peak shear demand PSD for beams of coupled shear walls (CSW) in mixed shear wall structures (MSW). Non-coupled lateral load resisting structures such as singular planar walls and cores will reduce primary bending moments in the coupled shear wall bents of MSW structures thereby increasing the degree of coupling. They will also change the location and magnitude of the maximum shear in and rotation of the coupling beams. These changes in the coupled wall bents may increase the demand on their performance beyond capacity. It is, therefore, important to have an indication of the change in the coupling beam design parameters at an early stage of the design. The proposed graphical method is based on the continuous medium theory and allows a rapid assessment of the structural behaviour of coupled shear wall bents in mixed shear wall structures that are subject to horizontal loading.
机译:提出了一种简单的分析方法,以确定混合剪力墙结构(MSW)中单个剪力墙(SSW)对耦合DoC程度和峰值剪力需求PSD的影响。非耦合的横向负载抵抗结构(例如奇异的平面壁和芯)将减少MSW结构的耦合剪力墙弯曲中的主弯矩,从而提高耦合程度。它们还将改变最大剪切力的位置和大小以及耦合梁的旋转。耦合壁弯中的这些变化可能会增加其性能超出容量的需求。因此,重要的是在设计的早期阶段就表明耦合梁设计参数的变化。所提出的图形化方法基于连续介质理论,可以快速评估混合剪力墙结构中承受水平荷载的耦合剪力墙弯头的结构性能。