首页> 外文期刊>Practice periodical on structural design and construction >Estimating In Situ Compressive Strength of Existing Concrete Structures
【24h】

Estimating In Situ Compressive Strength of Existing Concrete Structures

机译:估计现有混凝土结构的原位抗压强度

获取原文
获取原文并翻译 | 示例
       

摘要

An upper-bound and lower-bound approach using a combination of the rebound hammer test or Windsor probe test and ultrasonic pulse velocity test or core test for estimating in situ compressive strength of existing concrete structures is presented. A bias factor for each of the nondestructive tests and core test was introduced to account for the overestimation of characteristic in situ compressive strength by rebound hammer test and Windsor probe test and underestimation of characteristic in situ compressive strength by ultrasonic pulse velocity test and core test. In situ concrete testing results of 34 existing concrete structures aged 4-73 years were analyzed to obtain a range of each of the bias factors. Illustrative examples using this upper-bound and lower-bound approach for estimating characteristic in situ compressive strength of existing concrete structures are presented.
机译:提出了结合回弹锤试验或温莎探针试验和超声脉冲速度试验或岩心试验的上限和下限方法来估计现有混凝土结构的原位抗压强度。引入了每种无损检测和岩心试验的偏差因子,以解释回弹锤试验和Windsor探针试验对原位抗压强度的高估,以及超声波脉冲速度试验和岩心试验对原位抗压强度的低估。分析了34个4至73岁的现有混凝土结构的现场混凝土测试结果,以获取每个偏差因素的范围。给出了使用这种上限和下限方法估算现有混凝土结构的特性原位抗压强度的说明性示例。