Tests of V94.2 gas-turbine units (GTU) of the first PGU-450T plant of the North-West Cogeneration Plant of St. Petersburg are described. The parameters of the GTU and the regular features of their variation are determined in a wide range of operating conditions from idle running to full load. The GTU are characterized by high pressure losses in a cycle, high values of specific power and yield factor, and low concentrations of toxic gases in combustion products at operating modes ranging from 50% load to full load. Quite high efficiencies of the turbomachines are obtained under conditions close to the design ones. The maximum power of 173 MW is attained at a temperature of-10℃ and GTU efficiency of 34.5%.
机译:描述了圣彼得堡西北热电联产厂的第一台PGU-450T厂的V94.2燃气轮机(GTU)的测试。 GTU的参数及其变化的常规特征是在从空转到满负荷的各种运行条件下确定的。 GTU的特征在于,在50%负载到满负载的工作模式下,循环中的压力损失高,比功率和屈服因数高,燃烧产物中的毒气浓度低。在接近设计条件的条件下,涡轮机的效率很高。在-10℃的温度和GTU效率为34.5%的情况下,最大功率为173 MW。