Results of updating the reducer between the LPC and the condenser involving removal of lens compensators and stiffening of the bar and rib frames are presented. Air inflows into the vacuum system through cracks in welded joints of flexible elements with total welded length of 240 m are lowered considerably by replacing them by stiff sheet structures. Computations of the thermal and stress-strain states of the system are performed.
机译:给出了在LPC和聚光镜之间更新减速器的结果,包括拆卸镜头补偿器以及加固杆和肋骨框架。通过用刚性片状结构代替柔性元件的焊接缝隙,使总焊接长度为240 m的空气进入真空系统,可大大降低空气的流入量。进行系统的热和应力应变状态的计算。