The causes of damage to the baffle pipes in BKZ-420-140PT-2 high-pressure drum boilers during combustion of Irsha-Borodin and Zheronskii coals are analyzed. Damage to the salt module pipes was caused by the buildup of internal sediments and untimely chemical washing of the baffles. Flaws and bulging of the clean module pipes in the constriction region are caused by insufficient flow velocities in the 76/62-mm diameter pipes and high thermal loads during burning of Zheronskii coal. The fundamental solution for increasing the reliability of the boilers is to rebuild them with conversion to dry slag removal.
机译:分析了Irsha-Borodin和Zheronskii煤燃烧过程中BKZ-420-140PT-2高压汽包锅炉折流板管道损坏的原因。盐模块管的损坏是由于内部沉淀物的堆积和挡板的不及时化学清洗造成的。狭窄区域中清洁模块管道的缺陷和膨胀是由于直径为76/62毫米的管道流速不足以及Zheronskii煤燃烧过程中的高热负荷引起的。提高锅炉可靠性的根本解决方案是将其改造为干渣去除方法。