It is shown that the identification of d-axis stator and field winding leakage inductance appears to be possible using standstill frequency-response rests with field open (applying voltage to the stator), and with the stator open (applying voltage to the field). Measurements of applied and induced voltages and currents to the excited winding form a sufficient set of data to identify the leakage inductances of both the stator and field windings. This method is illustrated and applied to limited published standstill frequency response test data. The results indicate a variation in leakage inductance, depending on the frequency of the test. The reasons for such variations are explored and hypothesized.
机译:结果表明,在静止的频率响应休止条件下,打开磁场(向定子施加电压)和打开定子(向磁场施加电压)时,似乎可以识别d轴定子和励磁绕组漏感。对励磁绕组施加和感应的电压和电流的测量形成了足够的数据集,以识别定子绕组和励磁绕组的漏感。说明了此方法,并将其应用于有限的已发布静止频率响应测试数据。结果表明漏感随测试频率的变化而变化。探索和假设了这种变化的原因。