Calpine Tiverton Power Associates L.P. operates a 265 MW natural gas-fired, combined-cycle generating station in Tiverton, Rhode Island. The plant, which entered commercial operation on October 1, 2000, features a 172 MW General Electric 7FA7241 combustion turbine, a Nooter/Eriksen three-pressure heat recovery steam generator (HRSG), a selective catalytic reduction (SCR) system for NO_x control, a 93 MW GE A-10 condensing steam turbine, and an air-cooled steam turbine condenser. Tiverton has had an average baseload heat rate since startup of 6960 Btu/kWh, an availability factor of 94.18 percent, scheduled outage factor of 4.52 percent, and forced outage factor of 1.27 percent. Because of frequent AGC (automatic generation control) operation, the capacity factor has averaged 73.87 percent. Permitted emission levels are 3.5 ppm for NO_x, 12 ppm for CO, and 10 ppm for ammonia slip, although the plant typically operates well below those limits.
机译:Calpine Tiverton Power Associates L.P.在罗得岛州Tiverton经营着一个265 MW的天然气联合循环发电站。该工厂于2000年10月1日投入商业运行,具有172兆瓦的通用电气7FA7241燃气轮机,诺特/埃里克森三压力热回收蒸汽发生器(HRSG),用于NO_x控制的选择性催化还原(SCR)系统,一台93兆瓦的GE A-10冷凝式蒸汽轮机和一个风冷式蒸汽轮机冷凝器。自启动以来,Tiverton的平均基本负荷热效率为6960 Btu / kWh,可用性系数为94.18%,计划中断系数为4.52%,强制中断系数为1.27%。由于频繁进行AGC(自动发电控制)操作,因此容量系数平均为73.87%。尽管工厂通常在低于这些限值的条件下运行,但允许的排放水平对于NO_x为3.5 ppm,对于CO为12 ppm,对于氨泄漏为10 ppm。