The steam surface condenser is an integral component at electric utilities and other facilities that generate power. It is also the point where highly pure condensate can potentially come in contact with very impure cooling water via a condenser tube leak. The consequences literally can be catastrophic for plant operations. This article outlines many of the factors that can influence condenser tube corrosion and the effects contaminant in-leakage can have on steam generating units. When contaminants enter a steam-generating system, the high temperatures will initiate many reactions. Magnesium chloride or sulfate salts react with water to produce a magnesium hydroxide precipitate, plus acid. This can cause the boiler water pH to fall well below neutral, which -- given the harsh conditions inside a boiler -- is potentially catastrophic. Oxygen converts the protective cuprous oxide film on the tube surfaces to cupric oxide, after which the ammonia complexes the copper and puts it in solution.
机译:蒸汽表面冷凝器是电力公司和其他发电设施中不可或缺的组件。在这一点上,高纯冷凝水可能会因冷凝器管泄漏而与非常不纯净的冷却水接触。从字面上看,后果可能对工厂运营造成灾难性影响。本文概述了许多可能影响冷凝器管腐蚀的因素,以及污染物泄漏对蒸汽发生装置的影响。当污染物进入蒸汽发生系统时,高温将引发许多反应。氯化镁或硫酸镁盐与水反应,生成氢氧化镁沉淀和酸。这可能导致锅炉水的pH值大大低于中性,鉴于锅炉内部的恶劣条件,这可能会造成灾难性后果。氧气将管表面的保护性氧化亚铜膜转化为氧化铜,然后氨将铜络合并置于溶液中。

著录项

  • 来源
    《Power Engineering》 |2009年第4期|p.30-35|共6页
  • 作者

    Brad Buecker;

  • 作者单位

    By Brad Buecker, Contributing Editor;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 13:45:23

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号