首页> 外文期刊>Photodiagnosis and Photodynamic Therapy >The effect of antimicrobial photodynamic therapy on shear bond strength of orthodontic bracket: An in vitro study
【24h】

The effect of antimicrobial photodynamic therapy on shear bond strength of orthodontic bracket: An in vitro study

机译:抗菌光动力治疗对矫正支架剪切粘合强度的影响:体外研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives: The aim of this study was to evaluate the effect of antimicrobial photodynamic therapy (aPDT) with methylene blue (MB) and indocyanine green (ICG) on bond strength of orthodontic brackets to enamel.Materials and methods: A total of 45 non-carious and sound human premolar teeth were used in this study. All teeth were examined under a stereomicroscope at x10 magnification. The samples were divided to 3 groups including no treatment (control group), aPDT with MB and 660 nm diode laser and aPDT with ICG and 808 nm diode laser. After aPDT procedure, orthodontic brackets were bonded to enamel surfaces. Then, the samples were thermocycled for 5000 cycles between 5 degrees and 55 degrees C in water bath. The brackets were then debonded using a universal testing machine. The adhesive remnant index (ARI) score and SEM microscope evaluation were assessed. One-way analysis of variance (ANOVA) with Post-hoc test were used to compare the SBS values among groups.Results: The highest SBS mean value was presented in group 1 (control) (31.98 +/- 6.36). Whereas, the lowest SBS mean value was observed in group 3 (aPDT with ICG) (24.11 +/- 5.78). There were significant differences in SBS values between control and aPDT groups (P 0.05). Some superficial porosity and irregularity was presented following aPDT on surface of enamel when examined by scanning electron microscope. The mode of failure was mostly score 0 and score 1 in all groups.Conclusion: MB and ICG mediated antimicrobial photodynamic therapy both reduced the bond strength of orthodontic brackets compared to control group.
机译:目的:本研究的目的是评估抗微生物光学疗法(APDT)与亚甲基蓝(MB)和吲哚菁绿(ICG)对牙龈牙龈强度的影响。材料和方法总共45个非在本研究中使用了龋齿和声音的人掠牙。在X10放大倍数下,在立体显微镜下检查所有牙齿。将样品分为3组,包括NO治疗(对照组),与MB和660nm二极管激光器APDT和ICG和808nm二极管激光器。在APDT过程之后,将正畸支架粘合到搪瓷表面上。然后,将样品在水浴中在5℃和55℃之间进行5000个循环。然后使用通用测试机器借助括号。评估粘合剂残留指数(ARI)得分和SEM显微镜评估。使用后HOC测试的单向分析(ANOVA)进行比较组中的SBS值。结果:最高SBS平均值在第1组(控制)(31.98 +/- 6.36)中呈现。然而,在第3组(APDT)中观察到最低SBS平均值(APDT)(24.11 +/- 5.78)。对照和APDT基团之间的SBS值有显着差异(P <0.05)。通过扫描电子显微镜检查时,在牙釉质表面上呈现一些表面孔隙率和不规则性。所有群体的失败模式大多数分数0和得分1。结论:Mb和ICG介导的抗微生物光动力学治疗与对照组相比,矫正矫正括号的粘合强度降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号